Polyethylene wear remains a major cause of aseptic loosening and subsequent revision of total knee arthroplasties (TKA). During implant development and evaluation, simulator wear tests provide valuable information on material and design performance of TKA but have not yet replicated the wear patterns seen in vivo. Recent studies indicate that the combination of contact forces, sliding velocity, and distance, impacts the wear outcome [1, 2]. However, the detailed role of sliding velocity between condyle and tibial plateau, in combination with axial loading, remained unresolved. We hypothesize that implant wear can be strongly correlated with the so-called FV-factor, the product of applied axial force and sliding velocity of the condyle on its tibial counterpart. The aim of this study was to look at wear pattern formation and overall volumetric material loss versus varying FV-factors.
Skip Nav Destination
ASME 2004 International Mechanical Engineering Congress and Exposition
November 13–19, 2004
Anaheim, California, USA
Conference Sponsors:
- Bioengineering Division
ISBN:
0-7918-4703-9
PROCEEDINGS PAPER
The Influence of Sliding Velocity on Wear of Total Knee Arthroplasties
Laura L. Borgstede,
Laura L. Borgstede
University of Illinois at Chicago
Search for other works by this author on:
Thorsten Schwenke,
Thorsten Schwenke
Rush University Medical Center
Search for other works by this author on:
Thomas P. Andriacchi,
Thomas P. Andriacchi
Stanford University
Search for other works by this author on:
Markus A. Wimmer
Markus A. Wimmer
Rush University Medical Center
Search for other works by this author on:
Laura L. Borgstede
University of Illinois at Chicago
Thorsten Schwenke
Rush University Medical Center
Thomas P. Andriacchi
Stanford University
Markus A. Wimmer
Rush University Medical Center
Paper No:
IMECE2004-59866, pp. 245-246; 2 pages
Published Online:
March 24, 2008
Citation
Borgstede, LL, Schwenke, T, Andriacchi, TP, & Wimmer, MA. "The Influence of Sliding Velocity on Wear of Total Knee Arthroplasties." Proceedings of the ASME 2004 International Mechanical Engineering Congress and Exposition. Advances in Bioengineering. Anaheim, California, USA. November 13–19, 2004. pp. 245-246. ASME. https://doi.org/10.1115/IMECE2004-59866
Download citation file:
5
Views
0
Citations
Related Proceedings Papers
Related Articles
Effect of Ligament Properties on Nonlinear Dynamics and Wear Prediction of Knee Prostheses
J Biomech Eng (February,2021)
Wear Testing of UHMWPE Tibial Components: Influence of Oxidation
J. Tribol (January,2000)
Conceptual Design for Condylar Guiding Features of a Total Knee Replacement
J. Med. Devices (June,2011)
Related Chapters
Some Recent Advances and Current Challenges in Joint-Replacement Tribology and UHMWPE Bearing Surfaces
Tribology of Mechanical Systems: A Guide to Present and Future Technologies
Operating Range
Design and Analysis of Centrifugal Compressors
Identifying the Models, OF, DV, Convergence Criteria, and Constraints
Engineering Optimization: Applications, Methods, and Analysis