Previous clinical publications have identified osteolysis and periprosthetic bone resorption around total knee and hip implants as a contributor to loss of implant fixation [1,2,3,4]. Fluid pressure near fixation screw holes has been studied for both its potential to drive osteolytic polyethylene debris into surrounding cancellous bone and its potential as an isolated mechanism for causing bone resorption [5,6,7]. The interaction between joint capsule pressure, cyclic loading, and lytic lesions near fixation screw holes has also been the focus of prior work [8]. Increases in joint capsule pressure and cyclic loading were both shown to cause fluid to migrate to the site of osteolytic lesions near screw holes, increasing pressure within the lesion. However, cyclic loading was not shown to increase the joint capsule driving pressure.
Skip Nav Destination
ASME 2012 Summer Bioengineering Conference
June 20–23, 2012
Fajardo, Puerto Rico, USA
Conference Sponsors:
- Bioengineering Division
ISBN:
978-0-7918-4480-9
PROCEEDINGS PAPER
Open-Sided Tibial Tray to Poly Insert Interface Does Not Generate Peripheral Fluid Flow Under Cyclic Loading
Mark Heldreth,
Mark Heldreth
DePuy Orthopaedics, Inc., Warsaw, IN
Search for other works by this author on:
Daren L. Deffenbaugh,
Daren L. Deffenbaugh
DePuy Orthopaedics, Inc., Warsaw, IN
Search for other works by this author on:
Erik Reber,
Erik Reber
DePuy Orthopaedics, Inc., Warsaw, IN
Search for other works by this author on:
Paul Rullkoetter
Paul Rullkoetter
University of Denver, Denver, CO
Search for other works by this author on:
Mark Heldreth
DePuy Orthopaedics, Inc., Warsaw, IN
Daren L. Deffenbaugh
DePuy Orthopaedics, Inc., Warsaw, IN
Erik Reber
DePuy Orthopaedics, Inc., Warsaw, IN
Paul Rullkoetter
University of Denver, Denver, CO
Paper No:
SBC2012-80498, pp. 999-1000; 2 pages
Published Online:
July 19, 2013
Citation
Heldreth, M, Deffenbaugh, DL, Reber, E, & Rullkoetter, P. "Open-Sided Tibial Tray to Poly Insert Interface Does Not Generate Peripheral Fluid Flow Under Cyclic Loading." Proceedings of the ASME 2012 Summer Bioengineering Conference. ASME 2012 Summer Bioengineering Conference, Parts A and B. Fajardo, Puerto Rico, USA. June 20–23, 2012. pp. 999-1000. ASME. https://doi.org/10.1115/SBC2012-80498
Download citation file:
3
Views
0
Citations
Related Articles
Do Capsular Pressure and Implant Motion Interact to Cause High Pressure in the Periprosthetic Bone in Total Hip Replacement?
J Biomech Eng (December,2011)
Partial Meniscectomy Changes Fluid Pressurization in Articular Cartilage in Human Knees
J Biomech Eng (February,2012)
Micromechanically Based Poroelastic Modeling of Fluid Flow in Haversian Bone
J Biomech Eng (February,2003)
Related Chapters
Introduction
Design of Mechanical Bearings in Cardiac Assist Devices
Introduction
Axial-Flow Compressors
Hydrodynamic Mass, Natural Frequencies and Mode Shapes
Flow-Induced Vibration Handbook for Nuclear and Process Equipment