The objective of this study was to determine the mechanical properties of the axillary pouch of the inferior glenohumeral ligament in the directions perpendicular (transverse) and parallel (longitudinal) to the longitudinal axis of the anterior band of the inferior glenohumeral ligament. A punch was used to excise one transverse and one longitudinal tissue sample from the axillary pouch of each cadaveric shoulder (n=10). Each tissue sample was preconditioned and then a load-to-failure test was performed. All tissue samples exhibited the typical nonlinear behavior reported for ligaments and tendons. Significant differences (p<0.05) were detected between the transverse and longitudinal tissue samples for ultimate stress (0.8±0.4 MPa and 2.0±1.0 MPa, respectively) and tangent modulus (5.4±2.9 MPa and 14.8±13.1 MPa, respectively). No significant differences (p>0.05) were observed between the ultimate strain (transverse: 23.5±11.5%, longitudinal: 33.3±23.6%) and strain energy density (transverse: 10.8±8.5 MPa, longitudinal: 21.1±15.4 MPa) of the transverse and longitudinal tissue samples. The ultimate stress determined for the longitudinal axillary pouch tissue samples was comparable to a previous study that reported it to be 5.5±2.0 MPa. The ratio of the longitudinal to transverse moduli (3.3±2.8) is considerably less than that of the medial collateral ligament of the knee (30) and interosseous ligament of the forearm (385), suggesting that the axillary pouch functions to stabilize the joint in more than just one direction. Future models of the glenohumeral joint and surgical repair procedures should consider the properties of the axillary pouch in its transverse and longitudinal directions to fully describe the behavior of the inferior glenohumeral ligament.
Skip Nav Destination
Article navigation
April 2004
Technical Papers
Bi-directional Mechanical Properties of the Axillary Pouch of the Glenohumeral Capsule: Implications for Modeling and Surgical Repair
Susan M. Moore, B.S.,
Susan M. Moore, B.S.
Musculoskeletal Research Center, Department of Orthopaedic Surgery, University of Pittsburgh
Search for other works by this author on:
Patrick J. McMahon, M.D.,
Patrick J. McMahon, M.D.
Musculoskeletal Research Center, Department of Orthopaedic Surgery, University of Pittsburgh
Search for other works by this author on:
Richard E. Debski, Ph.D.
Richard E. Debski, Ph.D.
Musculoskeletal Research Center, Department of Orthopaedic Surgery, University of Pittsburgh
Search for other works by this author on:
Susan M. Moore, B.S.
Musculoskeletal Research Center, Department of Orthopaedic Surgery, University of Pittsburgh
Patrick J. McMahon, M.D.
Musculoskeletal Research Center, Department of Orthopaedic Surgery, University of Pittsburgh
Richard E. Debski, Ph.D.
Musculoskeletal Research Center, Department of Orthopaedic Surgery, University of Pittsburgh
Contributed by the Bioengineering Division for publication in the JOURNAL OF BIOMECHANICAL ENGINEERING. Manuscript received by the Bioengineering Division April 21, 2003; revision received October 29, 2003. Associate Editor: L. Soslowsky.
J Biomech Eng. Apr 2004, 126(2): 284-288 (5 pages)
Published Online: May 4, 2004
Article history
Received:
April 21, 2003
Revised:
October 29, 2003
Online:
May 4, 2004
Citation
Moore, S. M., McMahon, P. J., and Debski, R. E. (May 4, 2004). "Bi-directional Mechanical Properties of the Axillary Pouch of the Glenohumeral Capsule: Implications for Modeling and Surgical Repair ." ASME. J Biomech Eng. April 2004; 126(2): 284–288. https://doi.org/10.1115/1.1695574
Download citation file:
Get Email Alerts
Simulating the Growth of TATA-Box Binding Protein-Associated Factor 15 Inclusions in Neuron Soma
J Biomech Eng (December 2024)
Effect of Structure and Wearing Modes on the Protective Performance of Industrial Safety Helmet
J Biomech Eng (December 2024)
Sex-Based Differences and Asymmetry in Hip Kinematics During Unilateral Extension From Deep Hip Flexion
J Biomech Eng (December 2024)
Related Articles
Development of a Force-Driven Distractor for Distraction Osteogenesis
J. Med. Devices (December,2011)
Design of a Compliant Steerable Arthroscopic Punch
J. Med. Devices (June,2010)
Tendon to Bone Healing: Differences in Biomechanical, Structural, and Compositional Properties Due to a Range of Activity Levels
J Biomech Eng (February,2003)
Determination of Optimal Graft Lengths for Posterior Cruciate Ligament Reconstruction—A Theoretical Analysis
J Biomech Eng (April,2003)
Related Proceedings Papers
Related Chapters
Introduction
Ultrasonic Methods for Measurement of Small Motion and Deformation of Biological Tissues for Assessment of Viscoelasticity
Synthesis and Characterization of Carboxymethyl Chitosan Based Hybrid Biopolymer Scaffold
International Conference on Mechanical and Electrical Technology, 3rd, (ICMET-China 2011), Volumes 1–3
mDFA Human Empirical Results
Modified Detrended Fluctuation Analysis (mDFA)