This study involved the development and testing of a system for the simultaneous in vitro measurement of tibiofemoral kinematics and patellofemoral kinematics and forces. Knee motion was tracked using a Vicon 370, and patellofemoral force was measured using a six degree-of-freedom transducer based on the design of Singerman et al. Using this system, twelve knee specimens were tested in supine leg extension under a simulated quadriceps force. The comprehensive set of results corresponds well to the individual results of previous studies. The measurement system will be of value in assessing the effects of total knee arthroplasty on patellar function.
Issue Section:
Joint/Whole Body
1.
Hsieh
, Y. F.
, Draganich
, L. F.
, Ho
, S. H.
, and Reider
, B.
, 1998
, “The effects of removal and reconstruction of the anterior cruciate ligament on patellofemoral kinematics
,” Am. J. Sports Med.
, 26
, pp. 201
–209
.2.
Ayers
, D. C.
, Dennis
, D. A.
, Johanson
, N. A.
, and Pellegrini
, V. D.
, 1997
, “Common complications of total knee arthroplasty
,” J. Bone Jt. Surg., Am. Vol.
, 79-A
, pp. 278
–311
.3.
Ahmed
, A. M.
, Burke
, D. L.
, and Yu
, A.
, 1983
, “In vitro measurement of static pressure distribution in synovial joints—part II: retropatellar surface
,” ASME J. Fluids Eng.
, 105
, pp. 226
–236
.4.
Huberti
, H. H.
, and Hayes
, W. C.
, 1984
, “Patellofemoral contact pressure: the influence of q-angle and tendofemoral contact
,” J. Bone Jt. Surg., Am. Vol.
, 66-A
, pp. 715
–724
.5.
Singerman
, R.
, Berilla
, J.
, and Davy
, D. T.
, 1995
, “Direct in vitro determination of the patellofemoral contact force for normal knees
,” ASME J. Biomech. Eng.
, 117
, pp. 8
–14
.6.
Singerman
, R.
, Berilla
, J.
, Archdeacon
, M.
, and Peyser
, A.
, 1999
, “In vitro forces in the normal and cruciate-deficient knee during simulated squatting motion
,” ASME J. Biomech. Eng.
, 121
, pp. 234
–242
.7.
Heegaard
, J.
, Leyvraz
, P.-F.
, Van Kampen
, A.
, Rakotomanana
, L.
, Rubin
, P. J.
, and Blankevoort
, L.
, 1994
, “Influence of soft tissues on patellar three-dimensional tracking
,” Clin. Orthop.
, 299
, pp. 235
–243
.8.
van Kampen
, A.
, and Huiskes
, R.
, 1990
, “The three-dimensional tracking pattern of the human patella
,” J. Orthop. Res.
, 8
, pp. 372
–382
.9.
Veress
, S. A.
, Lippert
, F. G.
, Hou
, M. C.
, and Takamoto
, T.
, 1979
, “Patellar tracking patterns measurement by analytical x-ray photogrammetry
,” J. Biomech.
, 12
, pp. 639
–650
.10.
Hirokawa
, S.
, 1991
, “Three-dimensional mathematical model analysis of the patellofemoral joint
,” J. Biomech.
, 24
, pp. 659
–671
.11.
Ahmad
, C. S.
, Kwak
, S. D.
, Ateshian
, G. A.
, Warden
, W. H.
, Steadman
, J. R.
, and Mow
, V. C.
, 1998
, “Effects of patellar tendon adhesion to the anterior tibia on knee mechanics
,” Am. J. Sports Med.
, 26
, pp. 715
–724
.12.
Hsu
, H.-C.
, Luo
, Z.-P.
, Rand
, J. A.
, and An
, K.-N.
, 1996
, “Influence of patellar thickness on patellar tracking and patellofemoral contact characteristics after total knee arthroplasty
,” J. Arthroplasty
, 11
, pp. 69
–80
.13.
Powers
, C. M.
, Lilley
, J. C.
, and Lee
, T. Q.
, 1998
, “The effects of axial and multi-plane loading of the extensor mechanism on the patellofemoral joint
,” Clin. Biomech.
, 13
, pp. 616
–624
.14.
Hsu
, H.-C.
, Luo
, Z.-P.
, Rand
, J. A.
, and An
, K.-N.
, 1997
, “Influence of lateral release on patellar tracking and patellofemoral contact characteristics after total knee arthroplasty
,” J. Arthroplasty
, 12
, pp. 74
–83
.15.
Singerman
, R.
, Berilla
, J.
, Kotzar
, G.
, Daly
, J.
, and Davy
, D. T.
, 1994
, “A six degree-of-freedom transducer for in vitro measurement of patellofemoral contact forces
,” J. Biomech.
, 27
, pp. 233
–238
.16.
Veldpaus
, F. E.
, Woltring
, H. J.
, and Dortmans
, L. J. M. G.
, 1988
, “A least-squares algorithm for the equiform transformation from spatial marker coordinates
,” J. Biomech.
, 21
, pp. 45
–54
.17.
Grood
, E. S.
, and Suntay
, W. J.
, 1983
, “A joint coordinate system for the clinical description of three-dimensional motions: application to the knee
,” ASME J. Biomech. Eng.
, 105
, pp. 126
–144
.18.
Cole
, G. K.
, Nigg
, B. M.
, Ronsky
, J. L.
, and Yeadon
, M. R.
, 1993
, “Application of the joint coordinate system to three-dimensional joint attitude and movement representation: a standardization proposal
,” ASME J. Biomech. Eng.
, 115
, pp. 344
–349
.19.
Oppold
, P. T.
, Price
, A. J.
, and Zavatsky
, A. B.
, 2002
, “Patellofemoral kinematics and forces in intact and replaced knee joints
,” Acta of Bioengineering and Biomechanics
, 4
(Suppl 1), pp. 315
–316
.20.
Hirokawa
, S.
, Solomonow
, M.
, Lu
, Y.
, Lou
, Z.-P.
, and D’Ambrosia
, R.
, 1992
, “Anterior-posterior and rotational displacement of the tibia elicited by quadriceps contraction
,” Am. J. Sports Med.
, 20
, pp. 299
–306
.21.
Kurosawa
, H.
, Walker
, P. S.
, Abe
, S.
, Garg
, A.
, and Hunter
, T.
, 1985
, “Geometry and motion of the knee for implant and orthotic design
,” J. Biomech.
, 18
, pp. 487
–499
.22.
Wilson
, D. R.
, Feikes
, J. D.
, Zavatsky
, A. B.
, and O’Connor
, J. J.
, 2000
, “The components of passive knee movement are coupled to flexion angle
,” J. Biomech.
, 33
, pp. 465
–473
.23.
van Eijden
, T. M. G. J.
, de Boer
, W.
, and Weijs
, W. A.
, 1985
, “The orientation of the distal part of the quadriceps femoris muscle as a function of the knee flexion-extension angle
,” J. Biomech.
, 18
, pp. 803
–809
.24.
Nisell
, R.
, Nemeth
, G.
, and Ohlsen
, H.
, 1986
, “Joint forces in extension of the knee: analysis of a mechanical model
,” J. Biomech.
, 57
, pp. 41
–46
.Copyright © 2004
by ASME
You do not currently have access to this content.