Background. Static deformation analysis and estimation of wall stress distribution of patient-specific cerebral aneurysms can provide useful insights into the disease process and rupture. Method of Approach. The three-dimensional geometry of saccular cerebral aneurysms from 27 patients (18 unruptured and nine ruptured) was reconstructed based on computer tomography angiography images. The aneurysm wall tissue was modeled using a nonlinear, anisotropic, hyperelastic material model (Fung-type) which was incorporated in a user subroutine in ABAQUS. Effective material fiber orientations were assumed to align with principal surface curvatures. Static deformation of the aneurysm models were simulated assuming uniform wall thickness and internal pressure load of . Results. The numerical analysis technique was validated by quantitative comparisons to results in the literature. For the patient-specific models, in-plane stresses in the aneurysm wall along both the stiff and weak fiber directions showed significant regional variations with the former being higher. The spatial maximum of stress ranged from as low as in a small aneurysm to as high as in a giant aneurysm. The patterns of distribution of stress, strain, and surface curvature were found to be similar. Sensitivity analyses showed that the computed stress is mesh independent and not very sensitive to reasonable perturbations in model parameters, and the curvature-based criteria for fiber orientations tend to minimize the total elastic strain energy in the aneurysms wall. Within this small study population, there were no statistically significant differences in the spatial means and maximums of stress and strain values between the ruptured and unruptured groups. However, the ratios between the stress components in the stiff and weak fiber directions were significantly higher in the ruptured group than those in the unruptured group. Conclusions. A methodology for nonlinear, anisotropic static deformation analysis of geometrically realistic aneurysms was developed, which can be used for a more accurate estimation of the stresses and strains than previous methods and to facilitate prospective studies on the role of stress in aneurysm rupture.
Skip Nav Destination
jia-lu@uiowa.edu
rharbaugh@psu.edu
ml-raghavan@uiowa.edu
Article navigation
February 2007
Technical Papers
Nonlinear Anisotropic Stress Analysis of Anatomically Realistic Cerebral Aneurysms
Baoshun Ma,
Baoshun Ma
Department of Biomedical Engineering, 1402 SC,
University of Iowa
, Iowa City, IA 52242
Search for other works by this author on:
Jia Lu,
Jia Lu
Department of Mechanical and Industrial Engineering,
jia-lu@uiowa.edu
University of Iowa
, Iowa City, IA 52242
Search for other works by this author on:
Robert E Harbaugh,
Robert E Harbaugh
Departments of Neurosurgery, and Engineering Science and Mechanics,
rharbaugh@psu.edu
Penn State University
, Hershey, PA 17033
Search for other works by this author on:
Madhavan L. Raghavan
Madhavan L. Raghavan
Department of Biomedical Engineering, 1402 SC,
ml-raghavan@uiowa.edu
University of Iowa
, Iowa City, IA 52242
Search for other works by this author on:
Baoshun Ma
Department of Biomedical Engineering, 1402 SC,
University of Iowa
, Iowa City, IA 52242
Jia Lu
Department of Mechanical and Industrial Engineering,
University of Iowa
, Iowa City, IA 52242jia-lu@uiowa.edu
Robert E Harbaugh
Departments of Neurosurgery, and Engineering Science and Mechanics,
Penn State University
, Hershey, PA 17033rharbaugh@psu.edu
Madhavan L. Raghavan
Department of Biomedical Engineering, 1402 SC,
University of Iowa
, Iowa City, IA 52242ml-raghavan@uiowa.edu
J Biomech Eng. Feb 2007, 129(1): 88-96 (9 pages)
Published Online: July 21, 2006
Article history
Received:
December 11, 2005
Revised:
July 21, 2006
Citation
Ma, B., Lu, J., Harbaugh, R. E., and Raghavan, M. L. (July 21, 2006). "Nonlinear Anisotropic Stress Analysis of Anatomically Realistic Cerebral Aneurysms." ASME. J Biomech Eng. February 2007; 129(1): 88–96. https://doi.org/10.1115/1.2401187
Download citation file:
Get Email Alerts
Cited By
A Computational Procedure to Derive the Curve of Carus for Childbirth Computational Modeling
J Biomech Eng (January 2023)
Regularization of a Mathematical Model of the Wheatley Heart Valve
J Biomech Eng (January 2023)
Related Articles
Obstruction-Induced Pulmonary Vascular Remodeling
J Biomech Eng (November,2011)
The Association of Wall Mechanics and Morphology: A Case Study of Abdominal Aortic Aneurysm Growth
J Biomech Eng (October,2011)
Automated Methodology for Determination of Stress Distribution in Human Abdominal Aortic Aneurysm
J Biomech Eng (October,2005)
Optimal Sensor Design Using Patient-Specific Images
J. Med. Devices (June,2010)
Related Proceedings Papers
Related Chapters
Ultrasound-Induced Treatment of Neurodegenerative Diseases across the Blood-Brain Barrier
Biomedical Applications of Vibration and Acoustics in Therapy, Bioeffect and Modeling
Experimental Studies
Nanoparticles and Brain Tumor Treatment
Introduction
Nanoparticles and Brain Tumor Treatment