Dynamic loading on articular joints is essential for the evaluation of the risk of the articulation degeneration associated with occupational activities. In the current study, we analyzed the dynamic constraint loading for the thumb during pipetting. The constraint loading is considered as the loading that has to be carried by the connective tissues of the joints (i.e., the cartilage layer and the ligaments) to maintain the kinematic constraints of the system. The joint loadings are solved using a classic free-body approach, using the external loading and muscle forces, which were obtained in an inverse dynamic approach combined with an optimization procedure in anybody. The constraint forces in the thumb joint obtained in the current study are compared with those obtained in the pinch and grasp tests in a previous study (Cooney and Chao, 1977, “Biomechanical Analysis of Static Forces in the Thumb During Hand Function,” J. Bone Joint Surg. Am., 59(1), pp. 27–36). The maximal compression force during pipetting is approximately 83% and 60% greater than those obtained in the tip pinch and key pinch, respectively, while substantially smaller than that obtained during grasping. The maximal lateral shear force is approximately six times, 32 times, and 90% greater than those obtained in the tip pinch, key pinch, and grasp, respectively. The maximal dorsal shear force during pipetting is approximately 3.2 and 1.4 times greater than those obtained in the tip pinch and key pinch, respectively, while substantially smaller than that obtained during grasping. Our analysis indicated that the thumb joints are subjected to repetitive, intensive loading during pipetting, compared to other daily activities.
Skip Nav Destination
e-mail: jwu@cdc.gov
Division of Orthopedic Research,
Division of Orthopedic Research,
Article navigation
August 2015
Technical Briefs
Analysis of the Constraint Joint Loading in the Thumb During Pipetting
John Z. Wu,
e-mail: jwu@cdc.gov
John Z. Wu
1
National Institute for Occupational Safety and Health
,1095 Willowdale Road
,MS-2027, Morgantown, WV 26505
e-mail: jwu@cdc.gov
1Corresponding author.
Search for other works by this author on:
Erik W. Sinsel,
Erik W. Sinsel
National Institute for Occupational Safety and Health
,1095 Willowdale Road
,MS-2027, Morgantown, WV 26505
Search for other works by this author on:
Kristin D. Zhao,
Division of Orthopedic Research,
Kristin D. Zhao
Biomechanics Laboratory
,Division of Orthopedic Research,
Mayo Clinic
,Rochester, MN 55905
Search for other works by this author on:
Kai-Nan An,
Division of Orthopedic Research,
Kai-Nan An
Biomechanics Laboratory
,Division of Orthopedic Research,
Mayo Clinic
,Rochester, MN 55905
Search for other works by this author on:
Frank L. Buczek
Frank L. Buczek
Lake Erie College of Osteopathic Medicine (LECOM)
,Erie, PA 16509
Search for other works by this author on:
John Z. Wu
National Institute for Occupational Safety and Health
,1095 Willowdale Road
,MS-2027, Morgantown, WV 26505
e-mail: jwu@cdc.gov
Erik W. Sinsel
National Institute for Occupational Safety and Health
,1095 Willowdale Road
,MS-2027, Morgantown, WV 26505
Kristin D. Zhao
Biomechanics Laboratory
,Division of Orthopedic Research,
Mayo Clinic
,Rochester, MN 55905
Kai-Nan An
Biomechanics Laboratory
,Division of Orthopedic Research,
Mayo Clinic
,Rochester, MN 55905
Frank L. Buczek
Lake Erie College of Osteopathic Medicine (LECOM)
,Erie, PA 16509
1Corresponding author.
Manuscript received January 2, 2015; final manuscript received March 24, 2015; published online June 9, 2015. Assoc. Editor: Zong-Ming Li.This material is declared a work of the U.S. Government and is not subject to copyright protection in the United States. Approved for public release; distribution is unlimited.
J Biomech Eng. Aug 2015, 137(8): 084501 (7 pages)
Published Online: August 1, 2015
Article history
Received:
January 2, 2015
Revision Received:
March 24, 2015
Online:
June 9, 2015
Citation
Wu, J. Z., Sinsel, E. W., Zhao, K. D., An, K., and Buczek, F. L. (August 1, 2015). "Analysis of the Constraint Joint Loading in the Thumb During Pipetting." ASME. J Biomech Eng. August 2015; 137(8): 084501. https://doi.org/10.1115/1.4030311
Download citation file:
Get Email Alerts
Cited By
Related Articles
Design of an Endoreactor for the Cultivation of a Joint-Like-Structure
J. Med. Devices (June,2009)
2020 Editors' Choice Papers
J Biomech Eng (July,2021)
Related Chapters
Introduction to Pipeline Systems
Pipeline Pumping and Compression Systems: A Practical Approach
Application of Water Pinch Technology for Water Minimization in Titanium Pigment Industry
International Conference on Mechanical and Electrical Technology, 3rd, (ICMET-China 2011), Volumes 1–3
Generating Synthetic Electrocardiogram Signals Withcontrolled Temporal and Spectral Characteristics
Intelligent Engineering Systems through Artificial Neural Networks Volume 18