1-20 of 80
Keywords: Measurements
Close
Follow your search
Access your saved searches in your account

Would you like to receive an alert when new items match your search?
Close Modal
Sort by
Journal Articles
Publisher: ASME
Article Type: Research-Article
J Biomech Eng. November 2018, 140(11): 111002.
Paper No: BIO-18-1051
Published Online: August 20, 2018
..., by assessing quantitatively their performance during TW and NW. Eighty children (6–10 years) participated in the study. Trunk acceleration data and nonlinear measures (recurrence quantification analysis (RQA), and multiscale entropy (MSE)) were used to characterize trunk postural control and motor complexity...
Journal Articles
Publisher: ASME
Article Type: Research-Article
J Biomech Eng. September 2018, 140(9): 091012.
Paper No: BIO-17-1548
Published Online: June 26, 2018
... . 10.1021/la903038a [20] Atefi , E. , Mann , J. A. , Jr. , and Tavana , H. , 2014 , “ Ultralow Interfacial Tensions of Aqueous Two-Phase Systems Measured Using Drop Shape ,” Langmuir , 30 ( 32 ), pp. 9691 – 9699 . 10.1021/la500930x [21] Weibel , E. R. , and Gomez , D...
Includes: Supplementary data
Journal Articles
Publisher: ASME
Article Type: Research-Article
J Biomech Eng. October 2018, 140(10): 101003.
Paper No: BIO-17-1348
Published Online: June 21, 2018
...) kinetics of a multisegment HAT model. 1 Corresponding author. Manuscript received August 8, 2017; final manuscript received May 6, 2018; published online June 21, 2018. Assoc. Editor: Joel D Stitzel. 08 08 2017 06 05 2018 Bioinstrumentation Biomechanics Measurements...
Journal Articles
Publisher: ASME
Article Type: Technical Briefs
J Biomech Eng. October 2018, 140(10): 104501.
Paper No: BIO-17-1523
Published Online: June 21, 2018
... was to enhance the device design by reducing the size of the device, and device design was enhanced by minimizing measurement errors through development of a new ergonomic left and right foot instrument located medial to the first MTPJ (instead of beneath the foot). The first MTPJ stiffness (N mm/kg radian...
Journal Articles
Publisher: ASME
Article Type: Research-Article
J Biomech Eng. August 2018, 140(8): 081006.
Paper No: BIO-17-1402
Published Online: June 1, 2018
... conditions, as increases in stretch yielded decreases in fluid pressurization following a contraction, resulting from counteracting Poisson effects. Model pressure also varied spatially, with the highest gradients located near aponeuroses. These findings may explain variability of in vivo IMP measurements...
Journal Articles
Publisher: ASME
Article Type: Research-Article
J Biomech Eng. August 2018, 140(8): 081007.
Paper No: BIO-18-1008
Published Online: June 1, 2018
... and for the Future ,” U.S. Department of Commerce, ESA Issue Brief No. 03-11 . http://www.esa.doc.gov/sites/default/files/stemfinalyjuly14_1.pdf [3] Kahan , L. G. , Guertler , C. , Blatnik , J. A. , and Lake , S. P. , 2017 , “ Validation of Single c-Arm Fluoroscopic Technique for Measuring...
Includes: Supplementary data
Journal Articles
Publisher: ASME
Article Type: Research-Article
J Biomech Eng. September 2018, 140(9): 091009.
Paper No: BIO-17-1458
Published Online: May 24, 2018
.... It is with this purpose in mind that we performed particle image velocimetry (PIV) measurements of velocity fields within flows through a simplified coronary bifurcation. Although the flow in this simplified bifurcation differs from the actual blood flow, it emulates the main fluid dynamic mechanisms found in hemodynamic...
Journal Articles
Publisher: ASME
Article Type: Technical Briefs
J Biomech Eng. September 2018, 140(9): 094501.
Paper No: BIO-17-1318
Published Online: May 24, 2018
... April 21, 2018; published online May 24, 2018. Assoc. Editor: Joel D. Stitzel. 20 07 2017 21 04 2018 Bioinstrumentation Biomechanics Measurements The use of in silico methods (e.g., finite element modeling) is becoming increasingly popular for the quantification of bone...
Journal Articles
Publisher: ASME
Article Type: Research-Article
J Biomech Eng. September 2018, 140(9): 091006.
Paper No: BIO-17-1384
Published Online: May 24, 2018
...Calvin Kuo; Jake Sganga; Michael Fanton; David B. Camarillo Wearable sensors embedded with inertial measurement units have become commonplace for the measurement of head impact biomechanics, but individual systems often suffer from a lack of measurement fidelity. While some researchers have focused...
Journal Articles
Publisher: ASME
Article Type: Research-Article
J Biomech Eng. July 2018, 140(7): 071011.
Paper No: BIO-17-1076
Published Online: May 10, 2018
... RPI is viewed as a potential alternative and explored in this study. Using the RPI measurements, total indentation distance (TID), creep indentation distance, indentation force, and the unloading slope, we have developed a numerical analysis procedure using the Oliver–Pharr (O/P) method to estimate...
Journal Articles
Publisher: ASME
Article Type: Technical Briefs
J Biomech Eng. June 2018, 140(6): 064501.
Paper No: BIO-17-1046
Published Online: April 30, 2018
...James R. Funk; Roberto E. Quesada; Alexander M. Miles; Jeff R. Crandall The inertial properties of a helmet play an important role in both athletic performance and head protection. In this study, we measured the inertial properties of 37 football helmets, a National Operating Committee on Standards...
Journal Articles
Publisher: ASME
Article Type: Research-Article
J Biomech Eng. June 2018, 140(6): 061013.
Paper No: BIO-17-1250
Published Online: April 30, 2018
... diseases such as sickle cell disease (SCD), malaria, or cancer. 09 06 2017 06 02 2018 Bioinstrumentation Biomechanics Cellular mechanics Biological systems design Measurements Biological systems control Red blood cells (RBCs) are often the target of hematologic diseases...
Includes: Supplementary data
Journal Articles
Publisher: ASME
Article Type: Research-Article
J Biomech Eng. June 2018, 140(6): 061012.
Paper No: BIO-17-1585
Published Online: April 4, 2018
... technique for measuring and simulating the biomechanical contributions of ligaments to elbow joint kinematics and stability. in vitro testing of cadaveric joints is enhanced by the incorporation of fully parametric virtual ligaments, which are used in place of the native joint stabilizers to characterize...
Journal Articles
Publisher: ASME
Article Type: Research-Article
J Biomech Eng. June 2018, 140(6): 061010.
Paper No: BIO-17-1449
Published Online: April 4, 2018
... [27] Hill , M. R. , Duan , X. , Gibson , G. A. , Watkins , S. , and Robertson , A. M. , 2012 , “ A Theoretical and Non-Destructive Experimental Approach for Direct Inclusion of Measured Collagen Orientation and Recruitment Into Mechanical Models of the Artery Wall ,” J. Biomech...
Journal Articles
Journal Articles
Publisher: ASME
Article Type: Research-Article
J Biomech Eng. June 2018, 140(6): 061003.
Paper No: BIO-17-1336
Published Online: March 19, 2018
... by comparing velocity distributions with previous measurements and simulations in simplified airway geometries. Simulation results provided detailed maps of the axial and secondary flow patterns at different cross sections of the airway tree. The vortex core regions in the airways were visualized using...
Journal Articles
Publisher: ASME
Article Type: Technical Briefs
J Biomech Eng. May 2018, 140(5): 054502.
Paper No: BIO-17-1381
Published Online: March 16, 2018
...Hsien-Shun Liao; Peter J. Wen; Ling-Gang Wu; Albert J. Jin Atomic force microscopy (AFM) has been used to measure cellular stiffness at different osmolarities to investigate the effect of osmotic pressure on cells. However, substantial direct evidence is essential to clarify the phenomena derived...
Journal Articles
Journal Articles
Publisher: ASME
Article Type: Technical Briefs
J Biomech Eng. May 2018, 140(5): 054501.
Paper No: BIO-17-1392
Published Online: March 2, 2018
... of real-time head impact data. Previous studies indicate that a custom-instrumented mouthpiece is a superior method for collecting accurate head acceleration data. The objective of this study was to evaluate the efficacy of mounting a sensor device inside an acrylic retainer form factor to measure six...
Journal Articles
Publisher: ASME
Article Type: Research-Article
J Biomech Eng. May 2018, 140(5): 051001.
Paper No: BIO-17-1237
Published Online: February 13, 2018
... to the center of the specimen. Refer to Appendix A for details on the design. Fig. 3 Test system schematic showing the major hardware and software components of the device and the data interconnections between them For measuring force response, six miniature S-beam load cells (Futek model LSB200...