This paper focuses on the effect on rack inlet air temperatures as a result of maldistribution of airflows exiting the perforated tiles located adjacent to the fronts of the racks. The flow distribution exiting the perforated tiles was generated from a computational fluid dynamics (CFD) tool called Tileflow (trademark of Innovative Research, Inc.). Both raised floor heights and perforated tile-free areas were varied in order to explore the effect on rack inlet temperatures. The flow distribution exiting the perforated tiles was used as boundary conditions to the above-floor CFD model. A CFD model was generated for the room with electronic equipment installed on a raised floor. Forty racks of data processing (DP) equipment were arranged in rows in a data center cooled by chilled air exhausting from perforated floor tiles. The chilled air was provided by four A/C units placed inside a room 12.1 m wide×13.4 m long. Because the arrangement of the racks in the data center was symmetric, only half of the data center was modeled. The numerical modeling for the area above the raised floor was performed using a commercially available finite control volume computer code called Flotherm (trademark of Flomerics, Inc.). The flow was modeled using the k-e turbulence model. Results are displayed to provide some guidance on the design and layout of a data center.

1.
The Uptime Institute, “Heat Density Trends in Data Processing, Computer Systems and Telecommunication Equipment” (white paper), www.uptimeinstitute.org.
2.
Schmidt, R., 2001, “Effect of Data Center Characteristics on Data Processing Equipment Inlet Temperatures,” Advances in Electronic Packaging 2001 (Proc. of IPACK ’01, The Pacific Rim/ASME International Electronic Packaging Technical Conference and Exhibition), Kauai, July, ASME, New York, Vol. 2, ASME Paper No. IPACK2001-15870, pp. 1097–1106.
3.
Schmidt, R., and Cruz, E., 2002, “Raised Floor Computer Data Center: Effect on Rack Inlet Temperatures of Chilled Air Exiting Both the Hot and Cold Aisles,” Proceedings of Itherm Conference, San Diego, June, pp. 580–594.
4.
Schmidt, R., and Cruz, E., 2002, “Raised Floor Computer Data Center: Effect on Rack Inlet Temperatures When High Powered Racks are Situated Amongst Lower Powered Racks,” IMECE Conference, New Orleans, Nov., ASME New York.
5.
Schmidt, R., and Cruz, E., 2003, “Raised Floor Computer Data Center: Effect on Rack Inlet Temperatures When Adjacent Racks are Removed,” Interpack Conference, Maui, July (to be published).
6.
Schmidt, R., and Cruz, E., 2003, “Raised Floor Computer Data Center: Effect on Rack Inlet Temperatures When Rack Flowrates are Reduced,” Interpack Conference, Maui, July (to be published).
7.
Patel, C., Bash, C., Belady, C., Stahl, L., and Sullivan, D., 2001, “Computational Fluid Dynamics Modeling of High Compute Density Data Centers to Assure System Inlet Air Specifications,” Advances in Electronic Packaging 2001 (Proc. of IPACK ‘01, The Pacific Rim/ASME International Electronic Packaging Technical Conference and Exhibition), Kauai, July, ASME, New York, Vol. 2, ASME Paper No. IPACK2001-15662, pp. 821–829.
8.
Patel, C., Sharma, R., Bash, C., and Beitelmal, A., 2002, “Thermal Considerations in Cooling Large Scale Computer Density Data Centers,” Itherm Conference, San Diego, June, pp. 767–776.
9.
Awbi
,
H. B.
, and
Gan
,
G.
,
1994
, “
Predicting Air Flow and Thermal Comfort in Offices
,”
ASHRAE J.
,
Feb.
, pp.
17
21
.
10.
Bullock
,
C. E.
, and
Phillip
,
F.
,
1996
, “
The Sistine Chapel: HVAC Design for Special-Use Buildings
,”
ASHRAE J.
,
38
(4), April, pp.
49
58
.
11.
Cinato, P., Bianco, C., Licciardi, L., Pizzuti, F., Antonetti, M., and Grossoni, M., 1998, “An Innovative Approach to the Environmental System Design for TLC Rooms in Telecopm Italia,” Intelec98.
12.
Kiff, P., 1995, “A Fresh Approach to Cooling Network Equipment,” Brit. Telecommun. Eng., July.
13.
Quivey, B., and Bailey, A. M., 1999, “Cooling of Large Computer Rooms—Design and Construction of ASCI10 TeraOps,” Interpack99, June, Maui.
14.
Schmidt, R., 1997, “Thermal Management of Office Data Processing Centers,” Advances in Electronic Packaging 1997 (Proc. of The Pacific Rim/ASME International Electronic Packaging Technical Conference, INTERpack ‘97), Kohala Coast, HI, June, ASME, New York, Vol. 2, ASME Paper No. EEP-Vol 19-2, pp. 1995–2010.
15.
Seymour, M., 1992, “Dynamic Design on Atria,” Build. Services, Jan., pp.
27
29
.
16.
Kang
,
S.
,
Schmidt
,
R.
,
Kelkar
,
K.
, and
Patankar
,
S.
,
2001
, “
A Methodology for the Design of Perforated Tiles in Raised Floor Data Centers Using Computational Flow Analysis
,”
IEEE-CPMT J.
,
24
(
2
), pp.
177
183
.
17.
Schmidt, R., Karki, K., Kelkar, K., Radmehr, A., and Patankar, S., 2001, “Measurements and Predictions of the Flow Distribution Through Perforated Tiles in Raised Floor Data Centers,” Advances in Electronic Packaging 2001 (Proc. of IPACK ‘01, The Pacific Rim/ASME International Electronic Packaging Technical Conference and Exhibition), Kauai, July, ASME, New York, Vol. 2, ASME Paper No. IPACK2001-15728, pp. 905–914.
18.
Flotherm Instruction Manual, Flomerics Ltd., UK.
You do not currently have access to this content.