The heat rejected and water evaporated in mechanical and natural draft cooling towers are critically evaluated by employing the Merkel, Poppe, and e–number-of-transfer-units methods of analysis, respectively, at different operating and ambient conditions. The importance of using a particular method of analysis when evaluating the performance characteristics of a certain fill material and subsequently employing the same analytical approach to predict cooling tower performance is stressed. The effect of ambient humidity and temperature on the performance of cooling towers employing the Merkel, e-NTU, and Poppe methods of analysis are evaluated.
Issue Section:
Gas Turbines: Advanced Energy Systems
1.
McKelvey, K. K., and Brooke, M., 1959, The Industrial Cooling Tower, Elsevier, Amsterdam.
2.
Merkel, F., “Verdunstungsku¨hlung,” 1925, VDI-Zeitchrift, Vol. 70, pp. 123–128.
3.
Osterle
, F.
, 1991
, “On the Analysis of Counter-Flow Cooling Towers
,” Int. J. Heat Mass Transfer
, 34
(4/5
), pp. 1313
–1316
.4.
Jaber
, H.
, and Webb
, R. L.
, 1989
, “Design of Cooling Towers by the Effectiveness-NTU Method
,” ASME J. Heat Transfer
, 111
, pp. 837
–843
.5.
Poppe, M., and Ro¨gener, H., 1991, “Berechnung von Ru¨ckku¨hlwerken,” VDI-Wa¨rmeatlas, pp. Mi 1–Mi 15.
6.
Kloppers, J. C., and Kro¨ger, D. G., 2001, “A Critical Cooling Tower Performance Evaluation,” 12th IAHR Symposium in Cooling Towers and Heat Exchangers, UTS, Sydney, Australia.
7.
Bosnjacovic, F., 1965, “Technische Thermodinmik,” Theodor Steinkopf, Dresden.
8.
Bourillot, C., 1983, “TEFERI, Numerical Model for Calculating the Performance of an Evaporative Cooling Tower,” EPRI Report CS-3212-SR, Electric Power Research Institute, Palo Alto.
9.
Baard, T. W., 1998, “Performance Characteristics of Expanded Metal Cooling Tower Fill,” M. Eng. thesis, University of Stellenbosch, Stellenbosch, South Africa.
10.
Berman, L. D., 1961, Evaporative Cooling of Circulating Water, 2nd Edition, Chap. 2, pp. 94–99, edited by H. Sawistowski, translated from Russian by R. Hardbottle, Pergamon, New York.
11.
Kro¨ger, D. G., 1998, Air-Cooled Heat Exchangers and Cooling Towers Thermal-Flow Performance, Evaluation and Design, PennWell Corp., Tulsa, OK.
12.
Bourillot, C., 1983, “On the Hypothesis of Calculating the Water Flowrate Evaporated in a Wet Cooling Tower,” EPRI Report CS-3144-SR, Electric Power Research Institute, Palo Alto.
13.
Grange, J. L., 1994, “Calculating the Evaporated Water Flow in a Wet Cooling Tower,” paper presented at the 9th IAHR Cooling Tower and Spraying Pond Symposium, von Karman Institute, Brussels, Belgium.
14.
Roth, M., 2001, “Fundamentals of Heat and Mass Transfer in Wet Cooling Towers. All Well Known or are Further Developments Necessary?” 12th IAHR Symposium in Cooling Towers and Heat Exchangers, UTS, Sydney, Australia.
15.
Ha¨ssler, R., 1999, “Einfluss von Kondensation in der Grenzschicht auf die Wa¨rme-und Stoffu¨bertragung an einem Rieselfilm,” Fortschritt-Berichte VDI, Reihe 3, Nr. 615.
16.
Feltzin, A. E., and Benton, D., 1991, “A More Exact Representation of Cooling Tower Theory,” CTI J., 12(2), pp. 8–26.
17.
Sutherland
, J. W.
, 1983
, “Analysis of Mechanical-Draught Counterflow Air/Water Cooling Towers
,” ASME J. Heat Transfer
, 105
, pp. 576
–583
.Copyright © 2004