Air-cooled steam condensers (ACSCs) are increasingly employed to reject heat in modern power plants. Unfortunately, these cooling systems become less effective under windy conditions and when ambient temperatures are high. A better understanding of the fundamental air flow patterns about and through such ACSCs is essential if their performance is to be improved under these conditions. The present numerical study models the air flow field about and through a particular ACSC. The performance of the fans is modeled with the aid of a novel numerical approach known as the “actuator disc model.” Distorted air flow patterns that significantly reduce fan performance in certain areas and recirculatory flows that entrain hot plume air are found to be the reasons for poor ACSC performance. It is found that the reduction in fan performance is the main reason for the poor ACSC performance while recirculation of hot plume air only reduces performance by a small amount.

1.
Kröger
,
D. G.
, 2004,
Air-Cooled Heat Exchanger and Cooling Towers
,
Penwell Corp.
,
Tulsa, OK
.
2.
Van Aarde
,
D. J.
, and
Kröger
,
D. G.
, 1990, “
Vloeiverliese deur ’n A-Raam Vinbuisbundel in ’n Lugverkoelde Kondensator
,” M.Sc.Eng thesis, University of Stellenbosch Stellenbosch, South Africa.
3.
Goldschagg
,
H. B.
, 1993, “
Lessons Learned From the World’s Largest Air Cooled Condenser
,”
EPRI Proceedings, International Symposium on Improved Technology for Fossil Power Plants—New and Retrofit Applications
,
Washington, D.C.
4.
Salta
,
C. A.
, and
Kröger
,
D. G.
, 1995, “
Effect of Inlet Flow Distortions on Fan Performance in Forced Draught Air-Cooled Heat Exchangers
,”
Heat Recovery Syst. CHP
0890-4332,
15
(
6
), pp.
555
561
.
5.
Duvenhage
,
K.
, and
Kröger
,
D. G.
, 1996, “
The Influence of Wind on the Performance of Forced Draft Air-Cooled Heat Exchangers
,”
J. Wind. Eng. Ind. Aerodyn.
0167-6105,
62
,
259
277
.
6.
Bredell
,
J. R.
,
Kröger
,
D. G.
, and
Thiart
,
G. D.
, 2006, “
Numerical Investigation of Fan Performance in a Forced Draft Air-Cooled Steam Condenser
,”
Appl. Therm. Eng.
1359-4311,
26
, pp.
846
852
.
7.
Coetzee
,
R. V.
, and
du Toit
,
C.
, 2000, “
Numerical Simulation of an Air-Cooled Heat Exchanger
,” B.Eng. thesis, Potchefstroom University for Christian Higher Education, Potchefstroom, South Africa.
8.
Bredell
,
J. R.
,
Kröger
,
D. G.
, and
Thiart
,
G. D.
, 2005, “
Numerical Investigation of Fan Performance in a Forced Draft Air-Cooled Steam Condenser
,” M.Sc.Eng. thesis, University of Stellenbosch, Stellenbosch, South Africa.
9.
Van Rooyen
,
J. A.
, and
Kröger
,
D. G.
, 2007, “
Performance Trends of an Air-Cooled Steam Condenser Under Windy Conditions
,” M.Sc.Eng. thesis, University of Stellenbosch, Stellenbosch, South Africa.
You do not currently have access to this content.