A trigger probe measurement system and measurement methodology are developed for kinematic self-calibration of micro/meso-scale machine tools (mMTs). The trigger probe detects the contact between a spindle-mounted stylus and a table-mounted planar artifact. The trigger probe system is small enough to be easily mounted on an mMT. The measurement methodology is divided into off-machine and on-machine measurements. The off-machine measurements are only needed for the first calibration. Recalibration requires only the on-machine measurements to be repeated, thereby reducing recalibration time. The measurement system and methodology are implemented with existing kinematic modeling, error parameter estimation, and compensation techniques for the experimental calibration of a three-axis mMT. The measurement system error is evaluated and experimentally measured. Cutting tests are used to validate the performance of the calibration methodology.

1.
Vogler
,
M. P.
,
Liu
,
X.
,
Kapoor
,
S. G.
,
DeVor
,
R. E.
, and
Ehmann
,
K. F.
, 2002, “
Development of Meso-Scale Machine Tool (mMT) Systems
,” Technical Paper—Society of Manufacturing Engineers,
MS02–181
, pp.
1
9
.
2.
Subrahmanian
,
R.
, and
Ehmann
,
K. F.
, 2002, “
Development of a Meso-Scale Machine Tool (mMT) for Micro-Machining
,”
Proceedings of 2002 Japan-USA Symposium on Flexible Automation
, Hiroshima, Japan, July 14–19, Vol.
1
, pp.
163
169
.
3.
Werkmeister
,
J.
, and
Slocum
,
A.
, 2003, “
Design and Fabrication of the MesoMill: A Five-Axis Milling Machine for Meso-Scaled Parts
,”
Proceedings of Machines and Processes for Micro-Scale and Meso-Scale Fabrication, Metrology and Assembly—ASPE 2003 Winter Topical Meeting
, January 22–23, Gainesville, FL, pp.
79
82
.
6.
Furuta
,
K.
,
Ishikawa
,
Y.
,
Mikuriya
,
Y.
, and
Takahashi
,
Y.
, 1998, “
The Microfactory System in National R&D Project of MITI
,”
Proceedings of the International Workshop on Microfactories 1998
, December 7–9, Tsukuba, Japan, pp.
193
196
.
7.
Mooring
,
B.
,
Roth
,
Z.
, and
Driels
,
M.
, 1991,
Fundamentals of Manipulator Calibration
,
Wiley
,
New York
.
8.
Liang
,
J. C.
,
Li
,
H. F.
,
Yuan
,
J. X.
, and
Ni
,
J.
, 1997, “
A Comprehensive Error Compensation System for Correcting Geometric, Thermal, and Cutting Force-Induced Errors
,”
Int. J. Adv. Manuf. Technol.
0268-3768,
13
, pp.
708
712
.
9.
Srivastava
,
A. K.
,
Veldhuis
,
S. C.
, and
Elbestawit
,
M. A.
, 1995, “
Modeling Geometric and Thermal Errors in a Five-Axis CNC Machine Tool
,”
Int. J. Mach. Tools Manuf.
0890-6955,
35
(
9
), pp.
1321
1337
.
10.
Chen
,
J.-S.
, 1997, “
Fast Calibration and Modeling of Thermally-Induced Machine Tool Errors in Real Machining
,”
Int. J. Mach. Tools Manuf.
0890-6955,
37
(
2
), pp.
159
169
.
11.
Srinivasa
,
N.
, and
Ziegert
,
J. C.
, 1996, “
Automated Measurement and Compensation of Thermally Induced Error Maps in Machine Tools
,”
Precis. Eng.
0141-6359,
19
, pp.
112
132
.
12.
Bryan
,
J. B.
, 1982, “
A Simple Method for Testing Measuring Machine and Machine Tools Part 1: Principles and Applications
,”
Precis. Eng.
0141-6359,
4
(
2
), pp.
61
69
.
13.
Abbaszadeh-mir
,
Y.
,
Mayer
,
R. R.
,
Cloutier
,
G.
, and
Fortin
,
C.
, 2002, “
Theory and Simulation for the Identification of the Link Geometric Errors for a Five-Axis Machine Tool Using a Telescoping Magnetic Ball-Bar
,”
Int. J. Prod. Res.
0020-7543,
40
(
18
), pp.
4781
4797
.
14.
Yang
,
S. H.
,
Kim
,
K. H.
,
Park
,
Y. K.
, and
Lee
,
S. G.
, 2004, “
Error Analysis and Compensation for the Volumetric Errors of a Vertical Machining Center Using a Hemispherical Ball Bar Test
,”
Int. J. Adv. Manuf. Technol.
0268-3768,
23
, pp.
495
500
.
15.
Zhong
,
X. L.
,
Lewis
,
J. M.
, and
Nagy
,
F. L.
, 1996, “
Autonomous Robot Calibration Using a Trigger Probe
,”
Rob. Auton. Syst.
0921-8890,
18
, pp.
395
410
.
16.
Newman
,
W. S.
,
Birkhimer
,
C. E.
, and
Horning
,
R. J.
, 2000, “
Calibration of a Motoman P8 Robot Based on Laser Tracking
,”
Proceedings of the 2000 IEEE International Conference on Robotics and Automation
, April 24–27,
San Francisco
, pp.
3597
3602
.
17.
Lei
,
W. T.
, and
Hsu
,
Y. Y.
, 2002, “
Accuracy Test of Five-Axis CNC Machine Tool with 3D Probe-Ball. Part I: Design and Modeling
,”
Int. J. Mach. Tools Manuf.
0890-6955,
42
, pp.
1153
1162
.
18.
Chen
,
G.
,
Yuan
,
J.
, and
Ni
,
J.
, 2001, “
A Displacement Measurement Approach for Machine Geometric Error Asessment
,”
Int. J. Mach. Tools Manuf.
0890-6955,
41
, pp.
149
161
.
19.
Zhang
,
G. X.
,
Ouang
,
R.
, and
Lu
,
B.
, 1988, “
A Displacement Method for Machine Geometry Calibration
,”
CIRP Ann.
0007-8506,
37
, pp.
515
518
.
20.
Postlethwaite
,
S. R.
,
Ford
,
D. G.
, and
Morton
,
D.
, 1996, “
Dynamic Calibration of CNC Machine Tools
,”
Int. J. Mach. Tools Manuf.
0890-6955,
37
(
3
), pp.
287
294
.
21.
Castro
,
H. F. F.
, and
Burdekin
,
M.
, 2003, “
Dynamic Calibration of the Positioning Accuracy of Machine Tools and Coordinate Measuring Machine Using a Laser Interferometer
,”
Int. J. Mach. Tools Manuf.
0890-6955,
43
, pp.
947
954
.
22.
Wang
,
S.-M.
, and
Ehmann
,
K. F.
, 1999, “
Measurement Methods for the Position Errors of a Multi-Axis Machine. Part 1: Principles and Sensitivity Analysis
,”
Int. J. Mach. Tools Manuf.
0890-6955,
39
, pp.
951
964
.
23.
Lee
,
M. C.
, and
Ferreira
,
P. M.
, 2002, “
Auto-Triangulation and Auto-Trilateration. Part 1: Fundamentals
,”
Precis. Eng.
0141-6359,
26
, pp.
237
249
.
24.
Zhuang
,
H.
,
Motaghedi
,
S. H.
, and
Roth
,
Z. S.
, 1999, “
Robot Calibration with Planar Constraints
,”
Proceedings of the 1999 IEEE Conference on Robotics and Automation
, May 10–15,
Detroit
, pp.
805
810
.
25.
Ikits
,
M.
, and
Hollerbach
,
J. M.
, 1997, “
Kinematic Calibration Using a Plane Constraint
,”
Proceedings of the 1997 IEEE International Conference on Robotics and Automation
, April 20–25,
Albuquerque, NM
, pp.
3191
3196
.
26.
Chiu
,
Y.-J.
, and
Perng
,
M.-H.
, 2003, “
Self-Calibration of a General Hexapod Manipulator Using Cylinder Constraints
,”
Int. J. Mach. Tools Manuf.
0890-6955,
43
, pp.
1051
1066
.
27.
Wampler
,
C. W.
,
Hollarbach
,
J. M.
, and
Arai
,
T.
, 1995, “
An Implicit Loop Method for Kinematic Calibration and its Application to Closed-Loop Mechanisms
,”
IEEE Trans. Rob. Autom.
1042-296X,
11
(
5
), pp.
710
724
.
28.
Tajbakhsh
,
H.
,
Abadin
,
Z.
, and
Ferreira
,
P. M.
, 1997, “
L∞ Parameter Estimates for Volumetric Error in Models of Machine Tools
,”
Precis. Eng.
0141-6359,
20
, pp.
179
187
.
30.
Smith
,
S.
, and
Chetwynd
,
D.
, 1992,
Foundations of Ultraprecision Mechanism Design
,
Gordon and Breach
,
Philadelphia, PA
, Vol.
2
, Chap. 4.
31.
Freeman
,
P.
, 2003, “
Kinematic Calibration of Serial Link Mechanisms Using Polynomials
,” M.S. thesis, Washington University, St. Louis.
32.
Zhuang
,
H.
, and
Roth
,
Z. S.
, 1996,
Camera-Aided Robot Calibration
,
CRC
,
Boca Raton, FL
, pp.
134
136
.
33.
Slocum
,
A.
, 1992,
Precision Machine Design
,
Prentice–Hall
, Englewood Cliffs,
NJ
, pp.
401
402
.
34.
Vallance
,
R. R.
,
Morgan
,
C.
, and
Slocum
,
A. H.
, 2004, “
Precisely Positioning Pallets in Multi-Station Assembly Systems
,”
Precis. Eng.
0141-6359,
28
, pp.
218
231
.
35.
Culpepper
,
M. L.
,
Kartik
,
M. V.
, and
DiBiasio
,
C.
, 2005, “
Design of Integrated Eccentric Mechanisms and Exact Constraint Fixtures for Micron-Level Repeatability and Accuracy
,”
Precis. Eng.
0141-6359,
29
, pp.
65
80
.
36.
Hollarbach
,
J. M.
, 1989, “
A Survey of Kinematic Calibration
,”
The Robotics Review
,
O.
Khatib
,
J. J.
Craig
, and
T.
Lozano-Pérez
, eds.,
MIT Press
,
Cambridge, MA
, Vol.
1
.
You do not currently have access to this content.