This paper describes the design of the single entry tunneler (SET), devised to create a loop-shaped path in forearm subcutaneous tissue prior to placement of a vascular graft for hemodialysis access. Existing tunnelers are almost universally rigid and require high forces and multiple incisions to complete even the most simple path geometries. Furthermore, they are guided from the handle with limited tip-location feedback. This paper presents a three-stage tunneler design consisting of concentric nested tubes. The first stage is a straight stainless steel tube, the second is a smaller precurved nitinol tube, and the third is a straight inner nitinol tube. By deploying the stages in this order, SET is able to produce an approximately 180 deg looped path in tissue. A tip that is illuminated via a fiber optic cable provides visual feedback of the tip location. The SET outer diameter is limited to ensure that the precurved nitinol will not exceed its yield strain and not require an excessive force to be deployed from the straight outer stage. Therefore, a custom dilator was designed to increase the size of the tunnel to one suitable for the intended graft. A prototype of the SET tunneler and dilator system was manufactured. The device was shown to achieve the desired path in ballistics gel and was capable of at least 100 repeated-use cycles. By reducing the number of required incisions and improving ease of use during graft insertion procedures, the SET has the potential to greatly reduce the risk of infection and degree of unnecessary tissue trauma while increasing tunneling accuracy.
Skip Nav Destination
Article navigation
Design Of Medical Devices Conference Abstracts
Single Entry Tunneler (SET) for Hemodialysis Graft Procedures
Charles Keith Ozaki,
Charles Keith Ozaki
Brigham & Women’s Hospital
Search for other works by this author on:
Madalyn S. Berns
MIT
Elizabeth Tsai
MIT
Jesse Austin-Breneman
MIT
James C. Schulmeister
MIT
Edward Sung
MIT
Charles Keith Ozaki
Brigham & Women’s Hospital
Conor J. Walsh
MIT
J. Med. Devices. Jun 2011, 5(2): 027524 (1 pages)
Published Online: June 13, 2011
Article history
Online:
June 13, 2011
Published:
June 13, 2011
Citation
Berns, M. S., Tsai, E., Austin-Breneman, J., Schulmeister, J. C., Sung, E., Ozaki, C. K., and Walsh, C. J. (June 13, 2011). "Single Entry Tunneler (SET) for Hemodialysis Graft Procedures." ASME. J. Med. Devices. June 2011; 5(2): 027524. https://doi.org/10.1115/1.3590704
Download citation file:
Get Email Alerts
Cited By
Related Articles
On Modeling Assumptions in FEA of Stents
J. Med. Devices (June,2011)
Esophageal Prosthesis For Refractory Gastresophageal Reflux Disease Prevention
J. Med. Devices (June,2011)
Design and Prototyping of a Low-Cost Portable Mechanical Ventilator
J. Med. Devices (June,2010)
Development of A Medical Device for Quantitative Physical Therapies
J. Med. Devices (June,2008)
Related Proceedings Papers
Related Chapters
Introduction and Scope
High Frequency Piezo-Composite Micromachined Ultrasound Transducer Array Technology for Biomedical Imaging
EVALUATION OF THERMAL PROBE COOLING EFFECT BASED ON PIPELINE PARALLEL OPTICAL CABLE
Pipeline Integrity Management Under Geohazard Conditions (PIMG)
Experimental Studies
Nanoparticles and Brain Tumor Treatment