Skip Nav Destination
Issues
March 2010
ISSN 1932-6181
EISSN 1932-619X
In this Issue
Research Papers
Two-Dimensional FSI Simulation of Closing Dynamics of a Tilting Disk Mechanical Heart Valve
J. Med. Devices. March 2010, 4(1): 011001.
doi: https://doi.org/10.1115/1.4000876
Topics:
Disks
,
Dynamics (Mechanics)
,
Flow (Dynamics)
,
Fluid structure interaction
,
Platelets
,
Simulation
,
Valves
,
Shear stress
,
Heart valve prostheses
,
Fluid dynamics
Measurement and Optimization of Minimally Invasive Intervention Device Design Fitness Using a Multiobjective Weighted Isotropy Index
J. Med. Devices. March 2010, 4(1): 011002.
doi: https://doi.org/10.1115/1.4001107
Topics:
Design
,
Optimization
An Active Foot-Ankle Prosthesis With Biomechanical Energy Regeneration
J. Med. Devices. March 2010, 4(1): 011003.
doi: https://doi.org/10.1115/1.4001139
Topics:
Engines
,
Motors
,
Prostheses
,
Robotics
,
Springs
,
Design
,
Levers
,
Screws
,
Biomechanics
An Advanced Patient Lift and Transfer Device for the Home
J. Med. Devices. March 2010, 4(1): 011004.
doi: https://doi.org/10.1115/1.4001255
Topics:
Control equipment
,
Design
,
Dynamic stability
,
Feedback
,
Mechanical admittance
,
Safety
,
Simulation
,
Simulation results
,
Stability
,
Static stability
Technical Briefs
Ultrafast Laser Micromachining of Latex for Balloon Angioplasty
J. Med. Devices. March 2010, 4(1): 014501.
doi: https://doi.org/10.1115/1.4000680
Topics:
Lasers
,
Latex
,
Micromachining
A Modified Footplate for the Kerrison Rongeur
Alim P. Mitha, Mohamed S. Ahmad, Sarah J. Cohen, Janet S. Lieberman, Martin R. Udengaard, Alexander H. Slocum, Jean-Valery C. E. Coumans
J. Med. Devices. March 2010, 4(1): 014502.
doi: https://doi.org/10.1115/1.4000594
Topics:
Bone
,
Cutting
,
Design
,
Engineering prototypes
,
Soft tissues
,
Surgery
,
Testing
,
Leakage
,
Instrumentation
,
Compression
Enabling Technology for Microvascular Stenting in Ophthalmic Surgery
J. Med. Devices. March 2010, 4(1): 014503.
doi: https://doi.org/10.1115/1.4001193
Design Innovation
RFID Pharmaceutical Tracking: From Manufacturer Through In Vivo Drug Delivery
J. Med. Devices. March 2010, 4(1): 015001.
doi: https://doi.org/10.1115/1.4000495
Topics:
Drugs
,
Health care
,
Biocompatibility
Design and Construction of a Portable Transcranial Magnetic Stimulation (TMS) Apparatus for Migraine Treatment
J. Med. Devices. March 2010, 4(1): 015002.
doi: https://doi.org/10.1115/1.4000616
Topics:
Brain
,
Circuits
,
Condensers (steam plant)
,
Construction
,
Current density
,
Design
,
Engines
,
Magnetic fields
,
Motors
,
Safety
A Novel In Vivo Joint Loading System to Investigate the Effect of Daily Mechanical Load on a Healing Anterior Cruciate Ligament Reconstruction
Mark Stasiak M. Eng, Carl Imhauser, Jonathan Packer, Asheesh Bedi, Robert Brophy, David Kovacevic, Kent Jackson, Xiang-Hua Deng, Scott Rodeo, Peter Torzilli
J. Med. Devices. March 2010, 4(1): 015003.
doi: https://doi.org/10.1115/1.4001158
Topics:
Anterior cruciate ligament
,
Bone
,
Displacement
,
Knee
,
Stress
,
Tendons