Skip Nav Destination
Close Modal
Update search
Filter
- Title
- Author
- Author Affiliations
- Full Text
- Abstract
- Keyword
- DOI
- ISBN
- ISBN-10
- ISSN
- EISSN
- Issue
- Journal Volume Number
- References
- Conference Volume Title
- Paper No
Filter
- Title
- Author
- Author Affiliations
- Full Text
- Abstract
- Keyword
- DOI
- ISBN
- ISBN-10
- ISSN
- EISSN
- Issue
- Journal Volume Number
- References
- Conference Volume Title
- Paper No
Filter
- Title
- Author
- Author Affiliations
- Full Text
- Abstract
- Keyword
- DOI
- ISBN
- ISBN-10
- ISSN
- EISSN
- Issue
- Journal Volume Number
- References
- Conference Volume Title
- Paper No
Filter
- Title
- Author
- Author Affiliations
- Full Text
- Abstract
- Keyword
- DOI
- ISBN
- ISBN-10
- ISSN
- EISSN
- Issue
- Journal Volume Number
- References
- Conference Volume Title
- Paper No
Filter
- Title
- Author
- Author Affiliations
- Full Text
- Abstract
- Keyword
- DOI
- ISBN
- ISBN-10
- ISSN
- EISSN
- Issue
- Journal Volume Number
- References
- Conference Volume Title
- Paper No
Filter
- Title
- Author
- Author Affiliations
- Full Text
- Abstract
- Keyword
- DOI
- ISBN
- ISBN-10
- ISSN
- EISSN
- Issue
- Journal Volume Number
- References
- Conference Volume Title
- Paper No
NARROW
Format
Article Type
Subject Area
Topics
Date
Availability
1-8 of 8
Keywords: kinematics
Close
Follow your search
Access your saved searches in your account
Would you like to receive an alert when new items match your search?
Sort by
Journal Articles
Journal:
Journal of Medical Devices
Publisher: ASME
Article Type: Research-Article
J. Med. Devices. March 2021, 15(1): 011101.
Paper No: MED-20-1148
Published Online: December 18, 2020
... for longitudinal bone reduction surgery. First, the inverse and forward kinematic models of the mechanism are investigated. Particularly, the forward kinematic is solved by applying Sylvester's dialytic method. Second, the velocity model is studied and its singular configurations are identified. The workspace...
Journal Articles
Journal:
Journal of Medical Devices
Publisher: ASME
Article Type: Design Of Medical Devices Conference Abstracts
J. Med. Devices. June 2011, 5(2): 027504.
Published Online: June 1, 2011
...Shahram Amiri; T. Derek. V. Cooke; Urs P. Wyss 01 06 2011 biomechanics bone kinematics orthotics prosthetics Better performance of total knee replacement requires normal kinematics and higher range of motion. A potential solution can be a surface-guided knee with asymmetric...
Journal Articles
Edmond H. M. Lou, Emma K. Brunton, Fraaz Kamal, Andreas Renggli, Kyle Kemp, Justin Lewicke, Dulai Sukhdeep, Joe M. Watt, John Andersen
Journal:
Journal of Medical Devices
Publisher: ASME
Article Type: Technical Briefs
J. Med. Devices. June 2011, 5(2): 024501.
Published Online: May 31, 2011
... 2010 08 03 2011 31 05 2011 31 05 2011 biomedical electronics data acquisition gait analysis kinematics low-power electronics medical disorders paediatrics Gait abnormalities manifest themselves in a variety of forms, several of which are not well understood. One...
Journal Articles
Journal:
Journal of Medical Devices
Publisher: ASME
Article Type: Design Of Medical Devices Conference Abstracts
J. Med. Devices. June 2009, 3(2): 027506.
Published Online: June 30, 2009
... mechanics can be used to describe the shape of the cannula, given the translations and axial angles of each tube base. Here, in order to aim the laser, we invert this relationship (obtaining the “inverse kinematic”), solving for the translations and axial angles of each tube, given a desired position...
Journal Articles
R. Dana Carpenter, Ph.D., Sandra J. Shefelbine, Ph.D., Jesus Lozano, BA, Julio Carballido-Gamio, Ph.D., Sharmila Majumdar, Ph.D., C. Benjamin Ma, MD
Journal:
Journal of Medical Devices
Publisher: ASME
Article Type: Technical Briefs
J. Med. Devices. December 2008, 2(4): 044501.
Published Online: November 7, 2008
...R. Dana Carpenter, Ph.D.; Sandra J. Shefelbine, Ph.D.; Jesus Lozano, BA; Julio Carballido-Gamio, Ph.D.; Sharmila Majumdar, Ph.D.; C. Benjamin Ma, MD There are few commonly used clinical techniques to quantify the rotational stability and joint contact kinematics in knees in vivo. A magnetic...
Journal Articles
Journal:
Journal of Medical Devices
Publisher: ASME
Article Type: Research Papers
J. Med. Devices. December 2008, 2(4): 041005.
Published Online: November 6, 2008
... the usage of the simulator is limited. Thus, simulator modifications were made to implement a wear test as outlined in ISO 14243, and to improve both user-friendliness of operation and cost of simulation. In particular, this involved modifying the implant holders and controlling implant kinematics during...
Journal Articles
Journal:
Journal of Medical Devices
Publisher: ASME
Article Type: Research Papers
J. Med. Devices. June 2008, 2(2): 021003.
Published Online: May 14, 2008
... with four degrees of freedom (DOFs) (three rotational DOFs and one translation DOF) is proposed in this paper. This spatial mechanism based on a bevel-gear wrist is remotely driven with three rotation axes intersecting at a remote rotation center (the MIS entry port). Forward and inverse kinematics...
Journal Articles
Journal:
Journal of Medical Devices
Publisher: ASME
Article Type: Research Papers
J. Med. Devices. December 2007, 1(4): 246–253.
Published Online: August 10, 2007
...Brian A. Garner, Ph.D.; Jaeho Shim, Ph.D.; Scott Wilson, BS Muscles actuating the shoulder girdle are important for stabilizing the scapula and coordinating phased kinematics of the shoulder complex. If these muscles become weak or imbalanced, joint instability and injury may result. Reliable...