Simulations and real decomposition experiments with hydrogen peroxide induced by dissolved iron and solar illumination were performed in a solar pilot plant with compound parabolic collectors designed for photo-Fenton wastewater treatment. The structure of a gray-box linear model aimed at reproducing system dynamics with parameters dependent on operating conditions when operating around prescribed set-points is proposed. This simple model relates the changes in hydrogen peroxide concentration due to changes in hydrogen peroxide injection, dissolved iron, and solar illumination. Based on this model, control of the hydrogen peroxide concentration at set points between 200-900mgL±10mgL under dynamic conditions (simultaneous decomposition and addition of hydrogen peroxide by a dosage pump), was achieved. Different basic approaches for controller actuation upon the frequency of the dosage pump were tested, ranging from a simple PI controller to a PI controller plus antiwindup action and feedforward control. From these basic approaches, conclusions can be drawn about the process’s behavior under closed-loop control.

1.
Gogate
,
P. R.
, and
Pandit
,
A. B.
, 2004, “
A Review of Imperative Technologies for Wastewater Treatment I: Oxidation Technologies at Ambient Conditions
,”
Adv. Environ. Res.
1093-0191,
8
, pp.
501
551
.
2.
Gogate
,
P. R.
, and
Pandit
,
A. B.
, 2004, “
A Review of Imperative Technologies for Wastewater Treatment II: Hybrid Methods
,”
Adv. Environ. Res.
1093-0191,
8
, pp.
553
597
.
3.
Legrini
,
O.
,
Oliveros
,
E.
, and
Braun
,
A. M.
, 1993, “
Photochemical Processes for Water Treatment
,”
Chem. Rev. (Washington, D.C.)
0009-2665,
93
, pp.
671
698
.
4.
Safarzadeh-Amiri
,
A.
,
Bolton
,
J. R.
, and
Cater
,
S. R.
, 1996, “
The Use of Iron in Advanced Oxidation Processes
,”
J. Adv. Oxid. Technol.
1203-8407,
1
, pp.
18
26
.
5.
Ruppert
,
G.
,
Bauer
,
R.
, and
Heisler
,
G.
, 1994, “
UV-O3, UV-H2O2, UV-TiO2 and the Photo-Fenton Reaction—Comparison of Advanced Oxidation Processes for Wastewater Treatment
,”
Chemosphere
0045-6535,
28
, pp.
1447
1454
.
6.
Bauer
,
R.
,
Waldner
,
G.
,
Fallmann
,
H.
,
Hager
,
S.
,
Klare
,
M.
,
Krutzler
,
T.
,
Malato
,
S.
, and
Maletzky
,
P.
, 1999, “
The Photo-Fenton Reaction and the TiO2∕UV Process for Wastewater Treatment—Novel Developments
,”
Catal. Today
0920-5861,
53
, pp.
131
144
.
7.
Blanco
,
J.
,
Malato
,
S.
,
Fernández
,
P.
,
Vidal
,
A.
,
Morales
,
A.
,
Trincado
,
P.
,
Oliveira
,
J. C.
,
Minero
,
C.
,
Musci
,
M.
,
Casalle
,
C.
,
Brunotte
,
M.
,
Tratzky
,
S.
,
Dischinger
,
N.
,
Funken
,
K. H.
,
Sattler
,
C.
,
Vincent
,
M.
,
Collares-Pereira
,
M.
,
Mendes
,
J. F.
, and
Rangel
,
C. M.
, 2000, “
Compound Parabolic Concentrator Technology Development to Commercial Solar Detoxification Applications
,”
Sol. Energy
0038-092X,
67
, pp.
317
330
.
8.
Malato
,
S.
,
Blanco
,
J.
,
Vidal
,
A.
, and
Richter
,
C.
, 2002, “
Photocatalysis With Solar Energy at a Pilot-Plant Scale: An Overview
,”
Appl. Catal., B
0926-3373,
37
, pp.
1
15
.
9.
Malato Rodríguez
,
S.
,
Blanco Gálvez
,
J.
,
Maldonado Rubio
,
M. I.
,
Fernández-Ibañez
,
P.
,
Alarcón Padilla
,
D.
,
Collares Pereira
,
M.
,
Farinha Mendes
,
J.
, and
Correia de Oliveira
,
J.
, 2004, “
Engineering of Solar Photocatalytic Reactors
,”
Sol. Energy
0038-092X,
77
, pp.
513
524
.
10.
Sychev
,
A. Y.
, and
Isaak
,
V. G.
, 1995, “
Iron Compounds and the Mechanisms of the Homogeneous Catalysis of the Activation of O2 and H2O2 and of the Oxidation of Organic Substrates
,”
Russ. Chem. Rev.
0036-021X,
64
, pp.
1105
1129
.
11.
Pignatello
,
J. J.
,
Liu
,
D.
, and
Huston
,
P.
, 1999, “
Evidence for an Additional Oxidant in the Photoassisted Fenton Reaction
,”
Environ. Sci. Technol.
0013-936X,
33
, pp.
1832
1839
.
12.
De Laat
,
J.
,
Truong Le
,
G.
, and
Legube
,
B.
, 2004, “
A Comparative Study of the Effects of Chloride, Sulfate and Nitrate Ions on the Rates of Decomposition of H2O2 and Organic Compounds by Fe(II)∕H2O2 and Fe(III)∕H2O2
,”
Chemosphere
0045-6535,
55
, pp.
715
723
.
13.
Fallmann
,
H.
,
Krutzler
,
T.
,
Bauer
,
R.
,
Malato
,
S.
, and
Blanco
,
J.
, 1999, “
Applicability of the Photo-Fenton Method for Treating Water Containing Pesticides
,”
Catal. Today
0920-5861,
54
, pp.
309
319
.
14.
Malato
,
S.
,
Blanco
,
J.
,
Vidal
,
A.
,
Alarcón
,
D.
,
Maldonado
,
M. I.
,
Cáceres
,
J.
, and
Gernjak
,
W.
, 2003, “
Applied Studies in Solar Photocatalytic Detoxification: An Overview
,”
Sol. Energy
0038-092X,
75
, pp.
329
336
.
15.
Krutzler
,
T.
,
Fallmann
,
H.
,
Maletzky
,
P.
,
Bauer
,
R.
,
Malato
,
S.
, and
Blanco
,
J.
, 1999, “
Solar Driven Degradation of 4-Chlorophenol
,”
Catal. Today
0920-5861,
54
, pp.
321
327
.
16.
Sagawe
,
G.
,
Lehnard
,
A.
,
Lubber
,
M.
,
Rochendorf
,
G.
, and
Bahnemann
,
D.
, 2001, “
The Insulated Solar Fenton Hybrid Process: Fundamental Investigations
,”
Helv. Chim. Acta
0018-019X,
84
, pp.
3742
3759
.
17.
Sarria
,
V.
,
Kenfack
,
S.
,
Guillod
,
O.
, and
Pulgarin
,
C.
, 2003, “
An Innovative Coupled Solar-Biological System at Field Pilot Scale for the Treatment of Biorecalcitrant Pollutants
,”
J. Photochem. Photobiol., A
1010-6030,
159
, pp.
89
99
.
18.
Oliveros
,
E.
,
Legrini
,
O.
,
Hohl
,
M.
,
Müller
,
T.
, and
Braun
,
A. M.
, 1997, “
Industrial Waste Water Treatment: Large Scale Development of a Light-Enhanced Fenton Reaction
,”
Chem. Eng. Process.
0255-2701,
36
, pp.
397
405
.
19.
Göb
,
S.
,
Oliveros
,
E.
,
Bossmann
,
S. H.
,
Braun
,
A. M.
,
Nascimento
,
C. A. O.
, and
Guardani
,
R.
, 2001, “
Optimal Experimental Design and Artificial Neural Networks Applied to the Photochemically Enhanced Fenton Reaction
,”
Water Sci. Technol.
0273-1223,
44
, pp.
339
345
.
20.
Fernández-Alba
,
A. R.
,
Hernando
,
D.
,
Agüera
,
A.
,
Cáceres
,
J.
, and
Malato
,
S.
, 2002, “
Toxicity Assays: A Way for Evaluating Aops Efficiency
,”
Water Res.
0043-1354,
36
, pp.
4255
4262
.
21.
Rodriguez
,
M.
,
Sarria
,
V.
,
Esplugas
,
S.
, and
Pulgarin
,
C.
, 2002, “
Photo-Fenton Treatment of a Biorecalcitrant Wastewater Generated in Textile Activities: Biodegradability of the Photo-Treatment Solution
.”
J. Photochem. Photobiol., A
1010-6030,
151
, pp.
129
135
.
22.
Malato
,
S.
,
Cáceres
,
J.
,
Fernández-Alba
,
A. R.
,
Piedra
,
L.
,
Hernando
,
M. D.
,
Agüera
,
A.
, and
Vial
,
J.
, 2003, “
Photocatalytic Treatment of Diuron by Solar Photocatalysis, Evaluation of Main Intermediates and Toxicity
,”
Environ. Sci. Technol.
0013-936X,
37
, pp.
2516
2525
.
23.
Parra
,
S.
,
Pulgarín
,
C.
, and
Malato
,
S.
, 2002, “
New Integrated Photocatalytic-Biological Flow System Using Supported TiO2 and Fixed Bacteria for the Mineralization of Isoproturon
,”
Appl. Catal., B
0926-3373,
36
, pp.
131
144
.
24.
APHA
,
AWWA
, and
WEF
, 1998,
Standard Methods for the Examination of Water and Waste Water
, 20th ed.,
United Book Press Inc.
,
Baltimore, MD
.
25.
Berenguel
,
M.
,
Rodríguez
,
F.
,
Acién
,
F. D.
, and
García
,
J. L.
, 2004, “
Model Predictive Control of pH in Tubular Photobioreactors
,”
J. Process Control
0959-1524,
14
, pp.
377
387
.
26.
Äström
,
K. J.
, and
Wittenmark
,
B.
, 1984,
Computer Controlled Systems
,
Prentice-Hall
,
Englewood Cliffs, NJ
.
27.
Camacho
,
E. F.
,
Berenguel
,
M.
, and
Rubio
,
F. R.
, 1997,
Advanced Control of Solar Plants
,
Springer-Verlag
,
London
.
28.
Berenguel
,
M.
,
Camacho
,
E. F.
,
García-Martín
,
F. J.
, and
Rubio
,
F. R.
, 1999, “
Temperature Control of a Solar Furnace
,”
IEEE Control Syst. Mag.
0272-1708,
19
, pp.
8
25
.
You do not currently have access to this content.