Abstract

The use of artificial roughness is an efficient and commercial way to appreciate the thermal performance from the collector to the air in solar air heater ducts, for numerous applications such as space-heating, crop-drying, and seasoning of timber industrial purpose. In this paper, the tentative inquiry on thermal enactment using new-fangled of three-sided roughened quadrilateral duct solar air heater having an alignment of multiple-v and transverse wire is performed and compared the outcomes with smooth duct air heater under similar operational circumstances. The modification of an arrangement and operational constraints is inspected within the restrictions, the moral of four-sided duct aspect ratio (W/H) = 8, the Reynolds number occupied from 3000 to 12,000, fraction of pitch to roughness height, P/e in the range of 10–25; ratio of roughness height to hydraulic diameter, e/D in the range of 0.018–0.042; at flow attack angle, α = 60 deg for constant moral of relative roughness width, (W/w) = 6. The augmentation on thermal efficiency in three-sided rugged duct is found to be 23–86% when compared to smooth duct, and the maximum thermal efficiency can occur at P/e = 10 and e/D = 0.042. The enhancement in air temperature flowing under three-sided roughened duct is found to be 49.27% more than that of a smooth duct. The instant innovative form of three-sided roughened solar air warmer would be preferable to those of a smooth solar air heater with respect to heat assignment.

References

1.
Kumar
,
D.
, and
Prasad
,
L.
,
2018
, “
Analysis on Optimal Thermohydraulic Performance of Solar Air Heater Having Multiple V-Shaped Wire Rib Roughness on Absorber Plate
,”
Int. Energy J.
,
18
, pp.
153
170
. 10.5541/eoguijt.277772
2.
Kumar
,
D.
, and
Prasad
,
L.
,
2017
, “
Heat Transfer Augmentation of Various Roughness Geometry Used in Solar Air Heaters
,”
Int. J. Mech. Eng. Technol.
,
12
, pp.
491
508
.
3.
Prasad
,
B. N.
,
2013
, “
Thermal Performance of Artificially Roughened Solar Air Heaters
,”
Sol. Energy
,
91
, pp.
9159
9167
. 10.1016/j.solener.2013.01.014
4.
Kumar
,
A.
, and
Layek
,
A.
,
2019
, “
Energetic and Exergetic Performance Evaluation of Solar Air Heater With Twisted Rib Roughness on Absorber Plate
,”
J. Cleaner Prod.
,
232
, pp.
617
628
. 10.1016/j.jclepro.2019.05.363
5.
Garg
,
H. P.
, and
Prakash
,
J.
,
1997
,
Solar Energy Fundamentals and Applications
,
Tata McGraw-Hill
,
New Delhi
.
6.
Garg
,
H. P.
, and
Prakash
,
J.
,
2000
,
Solar Energy Fundamentals and Applications
, 1st ed.,
Tata McGraw-Hill
,
New Delhi
.
7.
Bhatti
,
M. S.
, and
Shah
,
R. K.
,
1987
,
Turbulent and Transition Flow Convective Heat Transfer Handbook of Single Phase Convective Heat Transfer
,
Wiley
,
New York
.
8.
Duffie
,
J. A.
, and
Beckman
,
W. A.
,
1980
,
Solar Engineering of Thermal Processes
,
Wiley
,
New York
.
9.
Joule
,
J. P.
,
1861
, “
On the Surface Condensation of Steam
,”
Philos. Trans. R. Soc. London, Ser. A
,
151
, pp.
133
160
.
10.
Bergles
,
A. E.
,
Webb
,
R. L.
, and
Junkan
,
G. H.
,
1979
, “
Energy Conservation via Heat Transfer Enhancement
,”
Energy
,
4
(
2
), pp.
193
200
. 10.1016/0360-5442(79)90120-8
11.
Kumar
,
V.
, and
Prasad
,
L.
,
2019
, “
Thermal Performance Investigation of Three Sides Concave Dimple Roughened Solar Air Heaters
,”
Sol. Energy
,
188
, pp.
361
379
. 10.1016/j.solener.2019.06.008
12.
Prasad
,
K.
, and
Mullick
,
S. C.
,
1983
, “
Heat Transfer Characteristics of a Solar Air Heater Used for Drying Purposes
,”
Appl. Energy
,
13
(
2
), pp.
83
93
. 10.1016/0306-2619(83)90001-6
13.
Karwa
,
R.
,
2003
, “
Experimental Studies of Augmented Heat Transfer and Friction in Asymmetrically Heated Rectangular Ducts With Ribs on the Heated Wall in Transverse, Inclined, v-Continuous and v-Discrete Pattern
,”
Int. Commun. Heat Mass Transfer
,
30
(
2
), pp.
241
250
. 10.1016/S0735-1933(03)00035-6
14.
Gupta
,
D.
,
Solanki
,
S. C.
, and
Saini
,
J. S.
,
1997
, “
Thermo Hydraulic Performance of Solar Air Heaters With Roughened Absorber Plates
,”
Sol. Energy
,
61
(
1
), pp.
33
42
. 10.1016/S0038-092X(97)00005-4
15.
Saini
,
R. P.
, and
Saini
,
J. S.
,
1997
, “
Heat Transfer and Friction Factor Correlations for Artificially Roughened Ducts With Expanded Metal Mesh as Roughened Element
,”
Int. J. Heat Mass Transfer
,
40
(
4
), pp.
973
986
. 10.1016/0017-9310(96)00019-1
16.
Esen
,
H.
,
Ozgen
,
F.
,
Esen
,
M.
, and
Sengur
,
A.
,
2009
, “
Modelling of a New Solar Air Heater Through Least-Squares Support Vector Machines
,”
Expert System Appl.
,
36
(
7
), pp.
10673
10682
. 10.1016/j.eswa.2009.02.045
17.
Esen
,
H.
,
Ozgen
,
F.
,
Esen
,
M.
, and
Sengur
,
A.
,
2009
, “
Artificial Neural Network and Wavelet Neural Network Approaches for Modelling of a Solar Air Heater
,”
Expert System Appl.
,
36
(
8
), pp.
11240
11248
. 10.1016/j.eswa.2009.02.073
18.
Ozgen
,
F.
,
Esen
,
M.
, and
Esen
,
H.
,
2009
, “
Experimental Investigation of Thermal Performance of Double-Flow Solar Air Heater Having Aluminium Cans
,”
Renewable Energy
,
34
(
11
), pp.
2391
2398
. 10.1016/j.renene.2009.03.029
19.
Lau
,
S. C.
,
McMillian
,
R. D.
, and
Han
,
J. C.
,
1991
, “
Turbulent Heat Transfer and Friction in a Square Channel With Discrete rib Tabulators
,”
ASME J Turbomac.
,
113
(
3
), pp.
360
366
. 10.1115/1.2927884
20.
Prasad
,
B. N.
, and
Saini
,
J. S.
,
1988
, “
Effect of Artificial Roughness on Heat Transfer and Friction Factor in a Solar Air Heater
,”
Sol. Energy
,
41
(
6
), pp.
555
560
. 10.1016/0038-092X(88)90058-8
21.
Hans
,
V. S.
,
Saini
,
R. P.
, and
Saini
,
J. S.
,
2010
, “
Heat Transfer and Friction Factor Correlation for Solar Air Heater Duct Roughened Artificially With Multiple v-Ribs
,”
Sol. Energy
,
84
(
6
), pp.
898
911
. 10.1016/j.solener.2010.02.004
22.
Cortés
,
A.
, and
Piacentini
,
R.
,
1990
, “
Improvements of the Efficiency of a Bar Solar Collector by Means of Turbulence Promotors
,”
Appl. Energy
,
36
(
4
), pp.
253
261
. 10.1016/0306-2619(90)90001-T
23.
Momin
,
A. M. E.
,
Saini
,
J. S.
, and
Solanki
,
S. C.
,
2002
, “
Heat Transfer and Friction in Solar Air Heater Duct With V-Shaped rib Roughness on Absorber Plate
,”
Int. J. Heat Mass Transfer
,
45
(
16
), pp.
3383
3396
. 10.1016/S0017-9310(02)00046-7
24.
Prasad
,
B. N.
,
Kumar
,
A.
, and
Singh
,
K. D. P.
,
2015
, “
Optimization of Thermo-Hydraulic Performance in Three Sides Artificially Roughened Solar Air Heaters
,”
Sol. Energy
,
111
, pp.
313
319
. 10.1016/j.solener.2014.10.030
25.
Behura
,
A. K.
,
Prasad
,
B. N.
, and
Prasad
,
L.
,
2016
, “
Heat Transfer, Friction Factor and Thermal Performance of Three Sides Artificially Roughened Solar Air Heaters
,”
Sol. Energy
,
130
, pp.
46
59
. 10.1016/j.solener.2016.02.006
26.
Han
,
J. C.
,
1988
, “
Heat Transfer and Friction Characteristics in Rectangular Channels With Rib Turbulators
,”
ASME J. Heat Transfer
,
110
(
2
), pp.
321
328
. 10.1115/1.3250487
27.
ASHRAE Standard 93-97
,
1977
,
Method of Testing to Determine the Thermal Performance of Solar Collectors
,
ASHRAE Publication
,
New York
.
28.
Holman
,
J. P.
,
2007
,
Experimental Method for Engineers
,
McGraw Hill Book Company
,
New York
.
You do not currently have access to this content.